REQ-001
Application property address
Statutory form requirement
- Evidence preview and source
- 10 Banksia Way, Example Locality WA 6000
- BA1 application · Page 1
- Comparison
- Certificate of title: 10 Banksia Way
SYNTHETIC BA1 REVIEWER WORKSPACE
PlanScout surfaces a relevant evidence preview and exact source reference. The reviewer opens the source, completes the check and records the human outcome.
Evidence located does not mean requirement satisfied.
This synthetic case uses the BA1 — Application for Building Permit – Certified, supported by the BA3 — Certificate of Design Compliance.
Certified building permit pathway indicated, subject to permit-authority confirmation · $520,000 · Sample Build WA Pty Ltd
Not started
PlanScout has surfaced potential evidence and source references across this synthetic application pack. 0 of 18 configured requirements have a human outcome. 6 exceptions and dependencies are classified separately from the complete review workload.
Review every configured requirement, inspect the cited source and record a human outcome.
Requirements reviewed: 0 of 18
Not startedReview completion records that each configured check has received a human outcome. It is not a permit decision.
Evidence located means potential supporting evidence located by PlanScout and awaiting reviewer verification.
| Configured requirement | Requirement layer | PlanScout evidence status | Evidence preview and source | Comparison | Human review status | Action |
|---|---|---|---|---|---|---|
REQ-001 Application property address | Statutory form requirement | Potential supporting evidence located Street address identified | 10 Banksia Way, Example Locality WA 6000 BA1 application · Page 1 | Certificate of title: 10 Banksia Way | Awaiting review | |
REQ-002 Lot and deposited plan reference | Cross-document consistency check | Potential supporting evidence located Lot and plan reference identified | Lot 101 on Deposited Plan SAMPLE 999999 Certificate of title · Page 1 | BA1 application: same lot and plan | Awaiting review | |
REQ-003 Applicant authority | Local government intake requirement | Potential supporting evidence located Authority-to-act evidence located | Sample Build WA Pty Ltd Owner authority to act · Page 1 | BA1 applicant: Sample Build WA Pty Ltd | Awaiting review | |
REQ-004 Builder registration details | Statutory form requirement | Potential supporting evidence located Registration declaration located | BC SAMPLE 0001 Builder registration declaration · Page 1 | BA1 builder: Sample Build WA Pty Ltd | Awaiting review | |
REQ-005 Building classification | Statutory form requirement | Potential supporting evidence located Classification extracted | Class 1a dwelling and Class 10a garage BA1 application · Page 2 | BA3 certificate: same classifications | Awaiting review | |
REQ-006 Declared construction value | Cross-document consistency check | Potential supporting evidence located Declared value extracted | $520,000 BA1 application · Page 2 | Fee calculation: $520,000 | Awaiting review | |
REQ-007 Certificate of design compliance | Statutory form requirement | Potential supporting evidence located BA3 certificate located | Certificate present BA3 certificate · Page 1 | No comparison required | Awaiting review | |
REQ-008 Architectural drawing set | Statutory form requirement | Potential supporting evidence located Drawing set located | Revision D Architectural plans · Cover sheet | No comparison required | Awaiting review | |
REQ-009 Structural practitioner evidence | Professional judgement boundary | Potential supporting evidence located Structural design certificate located | Certificate present Structural design certificate · Page 1 | No comparison required | Awaiting review | |
REQ-010 Stormwater drainage plan | Local government intake requirement | Potential supporting evidence located Drainage plan located | Plan present Stormwater drainage plan · Sheet 1 | No comparison required | Awaiting review | |
REQ-011 Certificate drawing reference | Cross-document consistency check | Possible mismatch Architectural revision reference extracted | Revision C BA3 certificate · Page 2 | Uploaded drawing set: Revision D | Awaiting review | |
REQ-012 Energy evidence drawing revision | Cross-document consistency check | Possible mismatch Stamped drawing revision extracted | Revision C Energy-assessor-stamped plans · Cover sheet | Architectural drawing set: Revision D | Awaiting review | |
REQ-013 Insurance property address | Cross-document consistency check | Possible mismatch Insured property address extracted | 12 Banksia Way Home Indemnity Insurance certificate · Page 1 | BA1 application: 10 Banksia Way | Awaiting review | |
REQ-014 Prescribed levy evidence | Statewide prescribed requirement | Possible mismatch Project value and levy extracted | $500,000 value / $1,000 levy Construction Training Fund receipt · Page 1 | BA1 application: $520,000 | Awaiting review | |
REQ-015 Site-services coordination | Local government intake requirement | Evidence not located Water-meter annotation checked | No supporting evidence located Architectural site plan · Site plan sheet | Crossover plan: new crossover selected | Awaiting review | |
REQ-016 Network-provider service site plan | External-agency dependency | Evidence not located Connection evidence checked | No supporting evidence located Network-provider connection application · Page 1 | Connection application: present | Awaiting review | |
REQ-017 Prior planning approval or planning prerequisite | Local workflow check | Outside automated scope Applicant pathway statement located | Applicant states that no separate development approval is required. Applicant pathway statement or supporting declaration · Page 1 | Not applicable | Awaiting review | |
REQ-018 Performance-solution pathway evidence | Professional judgement boundary | Outside automated scope No determination recorded by this check | Outside configured automated scope NCC compliance schedule · Page 1 | Professional review required if applicable | Awaiting review |
REQ-001
Statutory form requirement
REQ-002
Cross-document consistency check
REQ-003
Local government intake requirement
REQ-004
Statutory form requirement
REQ-005
Statutory form requirement
REQ-006
Cross-document consistency check
REQ-007
Statutory form requirement
REQ-008
Statutory form requirement
REQ-009
Professional judgement boundary
REQ-010
Local government intake requirement
REQ-011
Cross-document consistency check
REQ-012
Cross-document consistency check
REQ-013
Cross-document consistency check
REQ-014
Statewide prescribed requirement
REQ-015
Local government intake requirement
REQ-016
External-agency dependency
REQ-017
Local workflow check
REQ-018
Professional judgement boundary
A PlanScout result is not a statutory conclusion. It identifies the evidence located, the configured check applied and the point requiring human review.
Property
Fictional Lot 101 on Deposited Plan SAMPLE 999999 · Fictional Volume SAMPLE 9999 / Folio 999
Permit and classification
Certified BA1 · Class 1a dwelling · Class 10a attached garage
Applicant
Sample Build WA Pty Ltd
Certification
Jordan Lee — Sample Building Certification Pty Ltd · BS SAMPLE 0001
Applicant indication
No separate development approval stated by the applicant.
PlanScout scope
Planning-pathway determination is outside the automated scope.
Reviewer action
Confirm the applicable planning pathway and whether any supporting approval evidence is required.
BA7
Post-completion form — not part of the current BA1 application-pack check
Application type
Certified BA1
PlanScout’s initial pathway concerns certified building permit application packs. It may identify evidence of a prior planning approval or an unresolved prerequisite, but it does not determine the planning pathway or assess planning merit.
18
Unreviewed
0
Sufficient
0
Insufficient
0
Other outcomes
Potential supporting evidence is reported separately from human outcomes. Review completion records that each configured check has received a human outcome. It is not a permit decision.
Work through every configured requirement, inspect the cited source and record a human outcome before determining the authorised next action.
External-agency evidence is tracked separately and is not automatically treated as a permit-authority requirement. The reviewer must confirm how it applies to this application.